Battery & BESS Cold Plate Sizer

Bernardi · LCP · CHT Class Reference Map (Preliminary Sizing)
1.01 MWh Utility BESS Rack (28x 1P36S) · Q_coupled = 46.17 kW · T_core,max = 40.0 °C · ΔT_unif = 0.32 K
Thermal Design OK — Cell core temperature, cell-to-cell uniformity, and dew-point margin within safe operating limits.
Design Heat Load
46.17 kW
Datasheet @ 25 °C: 55.81 kW BOL / 71.91 kW EOL
Peak Cell Core Temp
40.01 °C
Margin +4.99 K to 45 °C · Pulse 43.4 °C
Cell-to-Cell Uniformity
0.32 K · PASS
39.69 → 40.01 °C · Coolant ΔT 3.07 K
Cold-Plate Δp & Dew Guard
8.26 kPa · 8.0 L/min/mod
224 L/min sys · T_dew 13.2 °C (+4.85 K Safe)
3D Module Assembly & Bifilar Serpentine Cold-Plate CHT CHT Coupled · 1P36S Folded U-Module · 18.0 → 21.1 °C
Application Note: Coupled Bernardi electro-thermal battery & BESS sizer (Arrhenius/SOC/SOH DCIR + reversible entropic dU/dT + busbar Joule loss), 3D orthotropic cell-TIM-serpentine cold-plate CHT, adaptive RK4 pulse ODE, and barometric dew-point guard.
▸ Equations & Standards

Application Note: Solves the coupled electro-thermal energy balance of prismatic, cylindrical (21700 / 4680), and pouch battery modules cooled by bottom/dual serpentine Liquid Cold Plates (LCP), cylindrical side-snake ribbons, interleaved pouch cooling fins, or forced inter-cell air. Unlike simplified online I²R calculators that ignore reversible entropic heat, Arrhenius DCIR coupling, and end-of-life (EOL 80% SOH) aging, both the 25 °C datasheet chiller duty and the self-consistent coupled Arrhenius CHT equilibrium are reported side-by-side.

Bernardi (1985) Electro-Thermal Energy Balance & Coupled Arrhenius DCIR
Q_gen,cell(T) = I_cell² · R_DCIR(T, SOC, SOH) + s_op · I_cell · T_K · (−∂U_OCV / ∂T)_SOC,   s_op = +1 (Discharge), −1 (Charge)
R_DCIR(T, SOC, SOH) = R_25,BOL · exp[ (E_a / R_g) · (1/T_K − 1/298.15) ] · k_SOC(SOC) · [1 + (k_EOL,80 − 1) · (1 − SOH)/0.20]
Orthotropic Cell Biot Resistance & Closed-Form Bifilar Serpentine ϵ-NTU March
Bottom LCP: R_cell,int = H_cell / (3 · k_eff,y · A_foot)  |  Cylindrical Snake: R_cell,int = 1 / (8π · k_r · H_cell · η_wrap)  |  Pouch Fin: R_cell,int = t_cell / (12 · k_⊥ · A_face) + H_cell / (6 · k_∥ · 2 t_fin L_cell)
Counter-Serpentine: η_h = 1 − exp(−UA_seg / (2 C_f)),   Δ_i = (1 / C_f) ∑_{k=i}^{n_s−1} Q_wet,k,   C_f (T_out − T_in) ≡ Q_gen,mod − Q_amb,loss
  • 1st & 2nd Law invariants: Exact analytical segment enthalpy conservation (rel_err < 10⁻¹²) and strict temperature monotonicity (T_core ≥ T_base ≥ T_wall ≥ T_fluid ≥ T_in under exothermic load, reversing cleanly during net endothermic LTO discharge or low-rate NMC charge).
  • Model boundaries: Module cold-plate hydraulics resolve Gnielinski/Shah developing convection with 180° U-bend loss coefficients (K_bend = 1.2). Multi-rack container airflow maldistribution and 3D thermal runaway gas-venting CFD require dedicated pack qualification (UL 9540A / IEC 62619).
  • Verified Reference Benchmarks (1-Click Load into Solver):
  • Sources: Bernardi, Pawlikowski & Newman, J. Electrochem. Soc. 132 (1985) 5–12; Pesaran, J. Power Sources 110 (2002) 377–382; Gnielinski, VDI Heat Atlas G1 (2013); Shah & London, Laminar Flow Forced Convection in Ducts (1978); Sonntag, Z. Meteorol. 70 (1990).